Search results for "Radiation Detector"
showing 10 items of 53 documents
Evaluation of the Spectroscopic Performance of 3D CZT Drift Strip Detectors
2021
CdTe/CZT is an attractive and consolidated material with which to realize detectors with good efficiency and energy resolution, operating at room temperature and suitable for a large variety of applications such as medical imaging, nuclear security, and astrophysics. Right in this last field several spectro-imagers based on these CdTe/CZT detectors were mounted onboard space missions such as INTEGRAL, Swift, and NuSTAR for hard X and gamma-ray astrophysics. Much effort has been expended in the development of CZT spectroscopic imagers for obtaining sub-millimeter spatial resolution in three dimensions (3D) and high energy resolution up to 1 MeV. The motivations are mainly related to the poss…
Search for the exotic Θ+ resonance in the NOMAD experiment
2006
12 pages, 16 figures.-- PACS nrs.: 13.15.+g; 13.60.Le; 13.87.Fh; 14.40.Ev.-- ISI Article Identifier: 000243973100007.-- ArXiv pre-print available at: http://arxiv.org/abs/hep-ex/0612063.-- et al.
All-sky search in early O3 LIGO data for continuous gravitational-wave signals from unknown neutron stars in binary systems
2021
Rapidly spinning neutron stars are promising sources of continuous gravitational waves. Detecting such a signal would allow probing of the physical properties of matter under extreme conditions. A significant fraction of the known pulsar population belongs to binary systems. Searching for unknown neutron stars in binary systems requires specialized algorithms to address unknown orbital frequency modulations. We present a search for continuous gravitational waves emitted by neutron stars in binary systems in early data from the third observing run of the Advanced LIGO and Advanced Virgo detectors using the semicoherent, GPU-accelerated, binaryskyhough pipeline. The search analyzes the most s…
Gravitational-wave Detection and Parameter Estimation for Accreting Black-hole Binaries and Their Electromagnetic Counterpart
2020
We study the impact of gas accretion on the orbital evolution of black-hole binaries initially at large separation in the band of the planned Laser Interferometer Space Antenna (LISA). We focus on two sources: (i)~stellar-origin black-hole binaries~(SOBHBs) that can migrate from the LISA band to the band of ground-based gravitational-wave observatories within weeks/months; and (ii) intermediate-mass black-hole binaries~(IMBHBs) in the LISA band only. Because of the large number of observable gravitational-wave cycles, the phase evolution of these systems needs to be modeled to great accuracy to avoid biasing the estimation of the source parameters. Accretion affects the gravitational-wave p…
High Bias Voltage CZT Detectors for High-flux Measurements
2017
In this work, we present the performance of new travelling heater method (THM) grown CZT detectors, recently developed at IMEM-CNR Parma, Italy. Thick planar detectors (3 mm thick) with gold electroless contacts on CZT crystals grown by Redlen Technologies (Victoria BC, Canada) were realized, with a planar cathode covering the detector surface (4.1 x 4.1 mm(2)) and a central anode (2 x 2 mm(2)) surrounded by a guard ring electrode. The detectors, characterized by low leakage currents at room temperature (4.7 nA/cm(2) at 1000 V/cm), allow good room temperature operation even at high bias voltages (> 7000 V/cm). At low rates, the detectors exhibit an energy resolution around 4 % FWIEM at 59.5…
A study of the material in the ATLAS inner detector using secondary hadronic interactions
2011
The ATLAS inner detector is used to reconstruct secondary vertices due to hadronic interactions of primary collision products, so probing the location and amount of material in the inner region of ATLAS. Data collected in 7 TeV pp collisions at the LHC, with a minimum bias trigger, are used for comparisons with simulated events. The reconstructed secondary vertices have spatial resolutions ranging from ~ 200μm to 1 mm. The overall material description in the simulation is validated to within an experimental uncertainty of about 7%. This will lead to a better understanding of the reconstruction of various objects such as tracks, leptons, jets, and missing transverse momentum.
Calibration of advanced Virgo and reconstruction of the gravitational wave signal h(t) during the observing run O2
2018
In August 2017, Advanced Virgo joined Advanced LIGO for the end of the O2 run, leading to the first gravitational waves detections with the three-detector network. This paper describes the Advanced Virgo calibration and the gravitational wave strain h(t) reconstruction during O2. The methods are the same as the ones developed for the initial Virgo detector and have already been described in previous publications, this paper summarizes the differences and emphasis is put on estimating systematic uncertainties. Three versions of the h(t) signal have been computed for the Virgo O2 run, an online version and two post-run reprocessed versions with improved detector calibration and reconstruction…
Thermoelectric radiation detector based on a superconductor-ferromagnet junction : Calorimetric regime
2018
We study the use of a thermoelectric junction as a thermal radiation detector in the calorimetric regime, where single radiation bursts can be separated in time domain. We focus especially on the case of a large thermoelectric figure of merit ZT affecting significantly, for example, the relevant thermal time scales. This work is motivated by the use of hybrid superconductor/ferromagnet systems in creating an unprecedentedly high low-temperature ZT even exceeding unity. Besides constructing a very general noise model which takes into account cross correlations between charge and heat noise, we show how the detector signal can be efficiently multiplexed by the use of resonant LC circuits givi…
The ALICE Transition Radiation Detector: Construction, operation, and performance
2018
The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this paper the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/$c$ in p-Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both …
X-ray and gamma-ray astronomy with NTD germanium-based microcalorimeters
2002
We report on the performance of our NTD-Ge microcalorimeters. To date, the spectral resolution for x-ray and gamma-ray lines from radioactive sources and laboratory plasmas is 4.8 eV in the entire 1 - 6 keV band and 52 eV at 60 keV. Technical details responsible for this performance are presented as well as an innovative electro-thermal approach for enhancing count-rate capability.